U.K. Sampling
Gauges Ltd

MK 10 kit Closed sampling system

Sampling type
Closed
Valve size
4-inch
Sample size
Up to 1000 ml
Specifications
Sampling typeClosed
Valve size4-inch
Sample sizeUp to 1000 ml
Stainless steel tape, length × width30 m × 16 mm
Winder barrel diameter102 mm
Height of winder closed88 cm
Height of winder open124 cm
Height open with winding handle at the top position135 cm
Weight12 kg (fitted with DIN 100 flange)
Suitable for RVP sampling?Yes (UKSGL uses 16-oz and/or 500 ml Winchester bottles)
Suitable for bottle container?Yes
FeaturesCoupling As Requested
From Closed Sampling System MK 10 ATEX on VCV, March 2025 · Winder MK 10 brochure, July 2024 · Table - Kits brochure, January 2023 · Table - Winders brochure, January 2023

Certification

ATEX and IECEx certified as this kit.

The certificates cover the MK 10 winder together with the samplers and ancillaries listed in Table 2: ALSB-V 502, ALSB-V 1002, ALS 1089, RNS 1076, BTMS 1002, SR 2, WFR, Hand-operated vacuum pump. Another sampler used with this winder is not covered.

BTMS 302 is in this kit’s contents but not on the certificate.

Table 2 does not list it with the MK 10 winder. A kit supplied with it is not, in that configuration, a certified assembly.

ATEX certificate
CML 21ATEX6978X, Table 2
IECEx certificate
IECEx CML 21.0114X
ATEX marking
II 1 G Ex h IIC T3 Ga
IECEx marking
Ex h IIC T3 Ga
Ambient temperature
−20 °C to +70 °C
Condition of use
The earth lead is permanently attached and must be clamped to a suitable earth point before operation.

Every UKSGL product is designed and manufactured under ISO 9001:2015, LRQA approval 00002231.

In the kit

Documents

Need it adapted or modified? UKSGL adapts equipment to customer requirements. Describe what you need in your quote request.